TECHNICAL EVALUATION GUIDE
How to evaluate a gold leaching reagent before plant adoption
A useful reagent trial is not a single recovery number. It is a controlled comparison that records the ore, operating conditions, consumption, residue and safety requirements well enough for a technical team to make a repeatable decision.
1. Begin with a representative sample
Ore variability can overwhelm the apparent effect of a reagent. Record the sample source, lithology, head grade, sulphide content, preg-robbing potential, moisture and preparation method. Composite samples should reflect the material expected during actual operation rather than only the easiest or richest fraction.
2. Define a fair comparison
Compare against the current process or another documented baseline. Keep grind size, pulp density, pH, aeration, temperature, agitation, test duration and sampling intervals consistent unless the test is deliberately studying one of those variables. Use duplicates where practical and document every intentional deviation.
3. Measure more than recovery
- Gold recovery over time and final residue grade.
- Reagent consumption per tonne of ore.
- pH stability and any supporting reagent demand.
- Filtration, settling, carbon loading or downstream effects.
- Handling, storage, waste and water-treatment implications.
4. Treat laboratory results as screening evidence
A bottle-roll or column result may justify further work, but it does not guarantee plant performance. Equipment, water chemistry, recycle streams, residence-time distribution, seasonal ore changes and operator control can affect scale-up. Define a limited plant trial with sampling points, stop conditions and decision criteria before introducing a new reagent broadly.
5. Make the decision auditable
Keep the raw data, calculations, photos, sample identification, test protocol and signed review together. A procurement decision should consider technical performance, total process cost, supply consistency, batch documentation, transport requirements and the ability to reproduce the result—not a headline recovery percentage alone.
Plan an LX-01 evaluation